#826166 Posted 5/27/2026

Fire Station No. 1 Wind Retrofit Project, Dania Beach, FL

Owner Reference
26-009
Bid Date
Jun 26, 2026 at 10:00am
Questions Due By
June 19, 2026, 3:00pm
Pre-Bid
Recommended - 6/2/2026 @ 10:30am @ (for location please or )
Owner
City of Dania Beach, FL
Trades
Glass & Glazing Contractor: Glass Tinting, Glass Door, Window Installations, Repairs & Replacements, Door Service Contractor: Including Bay Doors, Fire Doors, Gates, Activating Devices & Overhead/Garage Door Opener, High Voltage Electrical Contractor (HVE): Electrician, Power Lines; Substation, Switchgear, Transmission/Power Lines, CC - Roofing Contractor, Facia Board & Soffit Replacement, Gutters, Downspouts, Snow Guards, Concrete Contractor: Pavement, Driveways, Sidewalks, Curbs, Gutters, Flatwork, ADA Ramps Pedestrian Improvements, CIP Concrete, Generator Contractor: Electrical & Power Provider, Backup Battery Systems & Uninterrupted Power Supply (UPS) Systems, CGC - *General Building Contractor GBC: Building Construction, Enclosed Structures; Opportunities for Subcontractors, CGC - *General Engineering Contractor GEC: Heavy & Civil Engineering Construction, Infrastructure; Opportunities for Subcontractors
Phase
Renovation, Remodel, Improvements, Upgrades
Duration
180 days

Description

The City of Dania Beach is soliciting bids for wind mitigation upgrades at Fire-Rescue Station No. 1, located at 116 West Dania Beach Blvd. The project includes structural retrofits and modifications to comply with current hurricane-resistant standards. The project includes, but is not limited to: A. Civil 1. Restore sidewalks, green areas, pavement markings and pavement after installing new conduits for new generator B. Structural 1. Perform repair work to the Fire Station No. 1 to meet wind mitigation requirements. 2. Structural work includes: replacement of doors, roll-up doors and roof; removal of existing roof hatch and close opening. 3. Installation of new roof access ladder. 4. Pour new concrete slab for new generator 5. Removal of some louvers and double door and close opening with CMU wall. 6. Replacement of louvers. C. Electrical 1. Removal of existing 80 kW gas generator. 2. Installation of new 250 kW emergency diesel generator unit with a 187 mph enclosure. 3. Removal of existing transfer switch. 4. Installation of new transfer switch purchased by the City 5. Removal existing generator annunciator. 6. Installation of new generator annunciator purchased by the City. 7 Installation of underground conduits and splices 8. Installation of grounding system. D. UTILITY COORDINATION (FPL) o The Contractor shall include all costs and coordination required for Florida Power & Light (FPL) activities, including but not limited to: Required inspections Temporary power disconnects Service reconnections o The Contractor shall coordinate all work directly with FPL and comply with their requirements. E. TESTING AND QUALITY CONTROL o The Contractor shall provide concrete cylinder testing for all structural concrete work associated with the project. o The Contractor shall also perform soil density test for: o Subgrade and base preparation for concrete slabs o Wall footing areas Envelope wall foundation areas (if applicable) F. UNDERGROUND UTILITIES VERIFICATION o Prior to construction, the Contractor shall perform underground utility locating and tracing to verify the location of all existing utilities. o The Contractor shall be responsible for field verification and protection of existing utilities during construction. G. FIRE ALARM SYSTEM INTEGRATION o The new generator system shall be fully integrated with the existing fire alarm system. o Scope shall include all required wiring, devices, controls, programming, and coordination necessary for proper system operation. H. HVAC CONTROL REQUIREMENTS o The Contractor shall provide and install air conditioning delay timers to ensure proper load management during generator operation. o Integration and sequencing with existing HVAC systems shall be included in the scope. I. CRANE OPERATIONS AND GENERATOR HANDLING o The Contractor shall include all costs associated with crane rental, mobilization, demobilization, permits, and rigging required for generator handling operations. o Scope shall include: Removal of the existing generator and relocation to a designated City of Dania Beach (CDB) trailer/storage area Coordination of all lifting operations, including required permits and safety measures Mobilization of crane equipment for placement of the new generator once the concrete slab are completed and ready o All operations shall comply with applicable safety regulations and site constraints.

Bonds required.

Contact

  • or to view contact name.
  • or to view phone number.
  • or to view email address.

Plans & Specifications

or to view plans and specification details.

CBS ID: 826166 | Published 5/27/2026 on Construction Bid Source

DISCLAIMER: The bid notifications listed on Construction Bid Source are compiled from various sources and updated daily. It is the responsibility of each user, whether browsing publicly or logged in, to contact the project owner directly for the purpose of bidding and obtaining additional project details. Construction Bid Source does not assume any responsibility for omissions or errors in the information provided.

Documents

DBE/HUB Outreach Ads

This project requires a Good Faith Effort (GFE) outreach. For information regarding Construction Bid Source performing a GFE for you, please call us toll free at (888) 988-1208