Sign in to your account

Need an account?

Reset your password

Remembered your password?

Create your account

Already have an account?

#826240 Posted 5/27/2026

TSA Equipment Relocation Phase II 23102 REBID, Corpus Christi, TX

Owner Reference
6448
Bid Date
Jun 3, 2026 at 02:30pm
Pre-Bid
Scheduled, Optional - 5/7/2026 @ 10:00am @ (for location please or )
Estimate
$6,730,000.00
Owner
City of Corpus Christi, TX
Trades
*General Building Contractor GBC: Building Construction, Enclosed Structures; Opportunities for Subcontractors, Floor Covering and Flooring Contractor, Including Carpet, Wood, Marble, Tile, Ceramic, Linoleum, Vinyl, High Voltage Electrical Contractor (HVE): Electrician, Power Lines; Substation, Switchgear, Transmission/Power Lines, Masonry Contractor, Precast Concrete; Mortar Repair, Tuckpointing, Brick Pointing, Finishing Joints, Stone Masonry Contractor: Block Wall, Chimneys, Retaining Walls, Low Voltage Electrical Contractor (LVE) <91V: Electrician, Fiberoptic, Wire & Cabling, Telephone, Cable Television (TV), Awning Contractor: Canopies, Carports, Shade Structures, Patio Covers, Pergolas, Arbors, Trellises, & Soffit, Raingutters Installation Contractor: Cladding, Siding & Decking: Installation & Repairs; Pressure Washing Buildings, *General Engineering Contractor GEC: Heavy & Civil Engineering Construction, Infrastructure; Opportunities for Subcontractors
Phase
Renovation, Remodel, Improvements, Upgrades

Description

1. Improvements to Room 1034 at Corpus Christi International Airport. a. Improvements include, but are not limited to, relocation or disposal of existing equipment and finishes; coordination with City Procured Contractor tasked with CT- 80 machine and appurtenances relocation to renovated Room 1034; Contractor to furnish and maintain appropriate and adequate dust control around scanning equipment during construction activities; floor repair where the existing TSA screening equipment is removed from ticketing lobby area; removal and storage or disposal of lights / diffusers as required for new fixtures; modifications to walls to accommodate for oversized baggage and TSA work space;Construction of one (1) opening in the exterior masonry wall of the terminal building for a 6-ft roll up door; Installation of appropriate doors and / or draft curtains for baggage handling equipment; Installation of baggage conveyor equipment from interior ticketing area to exterior of the terminal building for baggage and installation of appropriate doors and / or draft curtain, doors and draft curtain to be Windstorm Compliant; removal, salvage, and storage of existing rollup door on the exterior and fill in door space with masonry that matches existing exterior masonry wall; Installation of new electrical circuits for baggage equipment, to drop down from ceiling OR sawcut and extend service from existing check-in counter to new baggage equipment location; Furnish and install appropriate LED lighting and switches; Furnish and install security improvements, including but not limited to, access control card readers, cameras, panic bar hardware on doors as noted; Furnish and install exterior wall insulation and finish gypsum board, including tape/float/texture/paint; Furnish and install acoustic dropdown ceiling; Cleaning of existing floor and installation of new flooring. 2. Exterior Overhead Canopies for Rooms 1034 and 1044: a. Construct overheard canopies on the airside exterior of the Terminal Building. New canopies to include gutter system and lighting. Installation of oscillating fans under existing canopy structures. The Work includes Contractor providing a structure that is Windstorm Certification compliant as follows: 1) WINDSTORM CERTIFICATION: Project is in a designated catastrophe area and must obtain appropriate windstorm certification for Exterior Overhead Canopies and any other component that requires windstorm certification. a) Windstorm Information and Requirements. (1) 150 mph 3 second gusts, must uphold to new windstorm Code. (2) Contractor to submit Texas Department of Insurance (TDI) Application for Certificate of Compliance. (3) WPI-1; For New Construction or substantial alterations or additions to existing structures. (4) WPI-2; For alternations to existing building. (5) Email address: [email protected], (6) Website: https://www.tdi.texas.gov/wind/adopted-codes.html, (7) Risk Category I, (8) Minimum ultimate wind speed: 137 mph, (9) Exposure Category D. 3. Inbound Ticket Counter Conveyor (Room 1044 West Side) a. Construct inbound Ticket Counter Conveyor equipment on the West Side SA CT- 80 Scanner (Room 1044). Connection to existing conveyor system and other improvements as noted in the associated drawings.

Bonds required. Prevailing wages.

Contact

  • or to view contact name.
  • or to view phone number.
  • or to view email address.

Plans & Specifications

or to view plans and specification details.

CBS ID: 826240 | Published 5/27/2026 on Construction Bid Source

DISCLAIMER: The bid notifications listed on Construction Bid Source are compiled from various sources and updated daily. It is the responsibility of each user, whether browsing publicly or logged in, to contact the project owner directly for the purpose of bidding and obtaining additional project details. Construction Bid Source does not assume any responsibility for omissions or errors in the information provided.

Documents

DBE/HUB Outreach Ads

This project requires a Good Faith Effort (GFE) outreach. For information regarding Construction Bid Source performing a GFE for you, please call us toll free at (888) 988-1208