Hazard Mitigation Grant Program HMGP Pump Station 2, Miami, FL
- Owner Reference
- RPQ No: P16117
- Bid Date
- Jun 18, 2026 at 10:00am
- Owner
- County of Miami-Dade, FL
- Trades
- Stormwater Prevention Plan (SWPP), Regional Flood Planning Group (RFPG), Floodproofing & Flood Risk/Pollution Reduction, CGC - *General Building Contractor GBC: Building Construction, Enclosed Structures; Opportunities for Subcontractors, CGC - *General Engineering Contractor GEC: Heavy & Civil Engineering Construction, Infrastructure; Opportunities for Subcontractors
- Phase
- Renovation, Remodel, Improvements, Upgrades
Description
hardening and flood protection upgrades to Pump Station No. 2. The upgrades include, but are not limited to: 1. Louvers: Provide wind protection as shown in the Drawings and Specifications. 2. Doors and Windows: a. Above the Design Flood Elevation: Replace with wind-resistant doors and windows as shown in the Drawings and Specifications. b. Below Design Flood Elevation: Combination of flood-resistant doors and windows, wind-resistant doors and windows, flood gates, and wind protection shutters as shown in the Drawings and Specifications. 3. Pump Discharge Check/Control Valves: Provide redundant hydro-pneumatic power system and ancillaries for valve actuation as shown in the Drawings and Specifications. 4. Odor Control System: a. Provide bypass ducting to allow for connection of a temporary odor control system (by others) as shown in the Drawings and Specifications. Bypass provides isolation of the existing odor control system to allow maintenance/repair work to occur. b. Provide flood protection to electrical panels as shown in the Drawings and Specifications. 5. HVAC: a. Replace the cooling tower, install in an elevated platform, and provide wind protection panels as shown in the Drawings and Specifications. b. Replace exhaust fans as shown in the Drawings and Specifications. 6. Other work shown on the plans and specifications to provide a complete work, including but not limited to demolition, removal, and refurbishment of existing features as shown in the Drawings and Specifications. C. The Project also includes work to make Pump Station No. 2 more aesthetically pleasing.
Contact
- or to view contact name.
- or to view phone number.
Plans & Specifications
or to view plans and specification details.
CBS ID: 825920 | Published 5/26/2026 on Construction Bid Source
DISCLAIMER: The bid notifications listed on Construction Bid Source are compiled from various sources and updated daily. It is the responsibility of each user, whether browsing publicly or logged in, to contact the project owner directly for the purpose of bidding and obtaining additional project details. Construction Bid Source does not assume any responsibility for omissions or errors in the information provided.
Documents
DBE/HUB Outreach Ads
This project requires a Good Faith Effort (GFE) outreach. For information regarding Construction Bid Source performing a GFE for you, please call us toll free at (888) 988-1208