Sign in to your account

Need an account?

Reset your password

Remembered your password?

Create your account

Already have an account?

#825926 Posted 5/26/2026

MIA Bldg. 845 Interior Renovations, Miami, FL

Owner Reference
RPQ No AA081A-R
Bid Date
Jul 1, 2026 at 02:00pm
Pre-Bid
MANDATORY - 6/16/2026 @ 10:00am @ (for location please or )
Estimate
$593,985
Owner
County of Miami-Dade, FL
Trades
CA - HVAC Contractor: Heating Ventilating Air Conditioning & Controls, Duct Clean, Exhaust Systems, Air Handler/Air Chillers, RTU's, Door Service Contractor: Including Bay Doors, Fire Doors, Gates, Activating Devices & Overhead/Garage Door Opener, High Voltage Electrical Contractor (HVE): Electrician, Power Lines; Substation, Switchgear, Transmission/Power Lines, CF, Master Plumber - Plumbing Contractor: Water Supply, Reverse Osmosis (RO), Water Heaters, Water Meters, Leak Detection, Flow & Backflow, Acoustic , EF - Fire Protection: Fire Alarm, Smoke Detection & Fire Suppression Contractor, Fire Extinguishers, Pumps, Hydrants & Inspections, CGC - *General Building Contractor GBC: Building Construction, Enclosed Structures; Opportunities for Subcontractors
Phase
Renovation, Remodel, Improvements, Upgrades
Duration
180 days

Description

Scope of Work shall include, but not be limited to: Provide all labor, equipment and materials for interior renovations at Bldg 845 including: remove and replace existing fire rated double swing metal doors and hardware at main corridors at 2nd, 3rd, 4th, 5th and 6th floors. New doors shall be fire rated double swing metal/glass door assembly including hardware; Remove and replace existing double swing tenant doors on column grid lines "B.4" and between "1.8" and "1.2" at 2nd, 3rd, 4th and 5th floors. New doors shall be fire rated double swing metal/glass door assembly including hardware with glass sides lite; Provide new fire rated corridor at the existing mechanical rooms located at south side of the building at 3rd, 4th, 5th and 6th floors; Provide new fire rated interior partition to create a new vestibule for the existing freight elevator, located at south side of the building, at 3rd and 4th floors; Provide new fire rated single swing metal doors and hardware at south side of main corridor and existing freight elevator at 3rd and 4th floors; Provide fire stop assembly to seal floor penetrations of existing cables at telecommunications rooms from 2nd to 6th floors. Provide new smoke detectors in new corridors (two per corridor). CONTRACTOR shall review all documents, specifications, and scope of work provided by Miami-Dade Aviation Department (MDAD) for work to be completed. Please refer to the Plans & Technical Specifications for further description of the scope of work. Restrooms inside the building are available for use. The actual cost of the permits will be reimbursed from the dedicated allowance. All other costs should be included in the bidders base bid. There is no limit for the working hours (24 hours per day), but the working hours will be discussed and finalized at the pre-construction meeting. If some of the work is deemed disruptive, it might have to be done during off hours including midnight. Please see General Demolition Notes #20 on Cover Sheet of Plans for more information.

Bonds required.

Contact

  • or to view contact name.
  • or to view phone number.

Plans & Specifications

or to view plans and specification details.

CBS ID: 825926 | Published 5/26/2026 on Construction Bid Source

DISCLAIMER: The bid notifications listed on Construction Bid Source are compiled from various sources and updated daily. It is the responsibility of each user, whether browsing publicly or logged in, to contact the project owner directly for the purpose of bidding and obtaining additional project details. Construction Bid Source does not assume any responsibility for omissions or errors in the information provided.

Documents

DBE/HUB Outreach Ads

This project requires a Good Faith Effort (GFE) outreach. For information regarding Construction Bid Source performing a GFE for you, please call us toll free at (888) 988-1208