#819818 Posted 4/20/2026

Reconstruction of Shady Lane Substation, Bryan, TX

Owner Reference
018-07-26 Addendum 1
Bid Date
May 13, 2026 at 02:00pm
Questions Due By
5/6/2026 05:00:00 PM (CT)
Pre-Bid
MANDATORY - 4/28/2026 @ 09:30am @ (for location please or )
Owner
Bryan Texas Utilities (BTU)
Trades
Cleanup Contractor: Debris Removal, Obstruction Hauling, Building/Grounds/Structures/Water - Demolition & Hauling, High Voltage Electrical Contractor (HVE): Electrician, Power Lines; Substation, Switchgear, Transmission/Power Lines, Pole Installation Repair Contractor, Low Voltage Electrical Contractor (LVE) <91V: Electrician, Fiberoptic, Wire & Cabling, Telephone, Cable Television (TV), *General Engineering Contractor GEC: Heavy & Civil Engineering Construction, Infrastructure; Opportunities for Subcontractors
Phase
Renovation, Remodel, Improvements, Upgrades

Description

Contractor is responsible for removing the two wood pole structures that are the first structures of two separate transmission lines that are the first structure after the substation h-frame deadend. Contractor is further responsible for unloading, building concrete foundations and installation of two replacement steel deadend structures, removing old conductor, installing new conductor between the existing lines and the new substation deadend structures. Existing fiber optic cables into the substation from these lines will be partially removed and connected to new fiber facilities. Contractor shall meet with BTU Staff to receive on-site personal briefing prior to any fiber activity which interrupts the integrity of existing fiber facilities. Contractor will be responsible for removing the two existing transformers from the Shady Lane Substation in conjunction with Sunbelt-Solomon. Contractor will be responsible for transferring the two new transformers from their storage location at Tabor Substation (fm984 at Boatcallie Road, Bryan, TX) to Shady Lane Substation. Contractor must allow enough time in their schedule for final assembly and oil processing of the new transformers at the site. Contractor shall be responsible for field testing of the two new transformers once they are assembled. Contractor will then be responsible for the remaining activities necessary to commission the new transformers. Both transformers are presently overfilled with oil pending install and filling of radiators. Some assembly work may require temporary storage of oil. Final assembly consists of installing: Three high voltage bushings Three low voltage phase bushings and one neutral bushing Eight radiators, radiator support bracing and fans Silica gel breather. The following additional transformer final assembly may be done by either the substation construction contractor or the subcontracted transformer final assembly contractor: High voltage arrester bracket, three high voltage arresters and grounding loop Three low voltage arresters and grounding loop Neutral bushing grounding bus bar.

Bonds required. Prevailing wages.

Contact

  • or to view contact name.
  • or to view phone number.
  • or to view email address.

Plans & Specifications

or to view plans and specification details.

CBS ID: 819818 | Published 4/20/2026 on Construction Bid Source

DISCLAIMER: The bid notifications listed on Construction Bid Source are compiled from various sources and updated daily. It is the responsibility of each user, whether browsing publicly or logged in, to contact the project owner directly for the purpose of bidding and obtaining additional project details. Construction Bid Source does not assume any responsibility for omissions or errors in the information provided.

Documents

DBE/HUB Outreach Ads

This project requires a Good Faith Effort (GFE) outreach. For information regarding Construction Bid Source performing a GFE for you, please call us toll free at (888) 988-1208