#821405 Posted 4/28/2026

Roof Renovation - Stallings Elementary School, Stallings, NC

Bid Date
May 19, 2026 at 03:00pm
Questions Due By
5/11/2026 @ 2:00pm
Pre-Bid
MANDATORY - 4/30/2026 @ 10:00am @ (for location please or )
Owner
Union County Public Schools (UCPS)
DBE Goal
10%
Trades
*General Building Contractor GBC: Building Construction, Enclosed Structures; Opportunities for Subcontractors, Roofing Contractor, Facia Board & Soffit Replacement, Gutters, Downspouts, Snow Guards
Phase
Renovation, Remodel, Improvements, Upgrades

Description

SCOPE OF WORK a. The low slope roof areas denoted 01.04, 01.07, 01.09, 01.11, 01.13, 01.18, 01.22 are to be stripped of existing TPO membrane and have a 1.5 isocyanurate insulation mechanically attached on top of existing insulation, also install new cover board set in foam adhesive, a two-ply modified bitumen membrane and flashings in cold adhesive. The existing roof assembly on low slope roof area denoted 01.05 is to be removed down to the roof deck and install 1.5 minimum thickness tapered isocyanurate insulation, gypsum cover board and two ply modified bitumen. The low slope roof areas denoted 01.09A are to be stripped of existing TPO membrane and install new cover board mechanically attached to existing insulation and install a two-ply modified bitumen membrane and flashings in cold adhesive. All gutters and downspouts attached to low slope roofs are to be removed and replaced with new downspouts and gutters, include splash pans where the downspouts discharge on low slope roofs. For all metal roofs denoted 01.01, 01.02, 01.03, 01.06, 01.08, 01.10, 01.12, 01.19, 01.20, 01.21, 01.22, 01.24 : The existing boots and boot cover on vent stacks are to be removed and new boots and boot covers reinstalled. The existing fasteners are to be replaced with new fasteners and neoprene washers that are one size larger than the existing. The existing gutters and downspouts are to be cleaned of debris. Repair / repair deteriorated downspout and gutter as needed. The concrete columns and concrete wall face at front entry are to be pressure washed with environmentally friendly chemical applied as specified. The EIFS repairs include: Cutting and repair of EIFS walls 12 from low-slope roofs as indicated in the designs. Bevel cut minor EIFS cracks and repair with scratch coat. Pressure wash all EIFS surface with environmentally friendly chemical applied as specified. Re-coat all EIFS surfaces. Replace backer rods and caulk around wall vents in EIFS walls. All fan, vent and HVAC curbs are to be raised as needed to achieve 8 minimum flashing height. All gas lines are to be brushed clean and painted. Replace damaged line supports with new line supports under gas lines and electrical conduits. Condensation lines, where applicable, need to be supported by base strut 5' on center max. all condensate lines to be schedule 80 pvc and must have a p-trap at each unit discharge. Route condensation lines to nearest drain or gutter edge.

Bonds required.

Contact

  • or to view contact name.
  • or to view phone number.
  • or to view email address.

Plans & Specifications

or to view plans and specification details.

CBS ID: 821405 | Published 4/28/2026 on Construction Bid Source

DISCLAIMER: The bid notifications listed on Construction Bid Source are compiled from various sources and updated daily. It is the responsibility of each user, whether browsing publicly or logged in, to contact the project owner directly for the purpose of bidding and obtaining additional project details. Construction Bid Source does not assume any responsibility for omissions or errors in the information provided.

Documents

DBE/HUB Outreach Ads

This project requires a Good Faith Effort (GFE) outreach. For information regarding Construction Bid Source performing a GFE for you, please call us toll free at (888) 988-1208